M302 p1. Other possible causes are a bad stepper motor or cable. M302 p1

 
 Other possible causes are a bad stepper motor or cableM302 p1  the X motor

3 E40 ; set drive mapping. Set the temperature (and enable) using. g. The macro folder can divided into sub directories to more easily organise your macros by type. 4. Tools; M563 P1 S"Clay" D0 ; Define tool 1 M563 P2 S"plastic" D1 H2 ; Define tool 2 G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets Some common uses…. g macro is;Autoload filament macro. Thermostatic control is turned off ; Fan for the hotend M950 F1 C"out6" L0:1000 Q50 ; create fan 1 on pin out6 and set its frequency M106 P1 S1 H1 T45 C"Hotend" ; set fan 1 value. Actual. Tried setting up the extruder on drive 4 then on drive 3. M302 S60 (for M3 and M2 Series printers) M302 P1 for (for Ultra One printers) (this allows the printer to extrude with the hot end above 60 degrees and is only a temporary change). 8 is far too low for two reasons: 1. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. PROMEGA I have installed a BL Touch clone and it works with the direct commands. : till no luck with Extrusion Control jogging buttons. When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by… Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. the X motor. Heater 1 fault: temperature rising too slowly: expected 2. Only users with topic management privileges can see it. 455513e-8My printer has sat for a couple of months because well, moving. Here is a handy list of g-code commands Reply Quote. This was done on Marlin 2. M302 P1;G92 E0. What is the trigger word to tell the firmware that we are starting a new layer? KulitorumHow bout if you heat up the hotend to 180?Hi *, I hope that somebody can help me here. 23". 1 Reply Last reply Reply Quote 0. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. Sending T0 initiates the heater and then faults out. This topic has been deleted. . When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by…Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. gpIn[0]. [Note: parameter letter E is a special case, an E parameter must always be preceded by a. droftarts administrators @flyscha last edited by . Items 1 - 36 of 42. I made my own slicer for the concrete printer, but for some reason the layer change is not detected, so my "Last Layer Time" is not updated. Using Extruder-Motor by G-Code (after using M302 P1 to enable cold-extrusion) What catches my eyes is that the text "Heater1" etc. gcode" and run that from an SD card. M569 P1 S0 ; physical drive 1 goes forwards using default driver timings M569 P2 S1 ; physical drive 2 goes forwards using default driver timings. good evening . Let me explain better: I need to set the T0 value to 170/25 degrees as dummy to run the right Titan to verify the right amount of filament that extr. Part Type: Rear Main Seals. M302 P1 will disable the temperature check that disables the extruder when the nozzle is cold. Command "M302 P1" works properly. 294060 INTRODUCTION INTRODUCTION This manual contains information for post processor to create EIA/ISO program according to the machine. This document describes the commands that Klipper supports. 1 Reply Last reply Reply Quote 0. M570 S180 ; allow it 180 seconds before gving a heating warning and test hotends wont be tuned. Wood filament wont extrude / print below 200deg. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. G4 S1 ; wait for one second. 00°C/sec. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. Well broadly speaking I think this is the basis for the new UM3 bed probing, the probe presses on the glass which triggers a capacitative sensor underneath. 7. I would be very gratefull for any help. g. Here is a handy list of g-code commands [ reprap. 0. This manual describes the machines of the INTEGREX e-series, INTEGREX i-series, and VORTEX i-series. 0C, min. If you are using the web interface, go to the Gcode. GCode and RepRapFirmware. Suppose they are, in fact, 105mm apart. Re: How can I move E steppers? January 11, 2023 02:36AMI used the safety scissors to cut off the fingers of the severed hand then tried to give her the fingers. 0. Click to Enlarge. Macros also allow for naming gcodes with easier to remember names. Thermostatic control is turned off. 3 (3. Retract 150 mm of. Both Agisoft and Pix4d do some weird color smoothing that makes the meshes much less crisp looking. g ; Unload to above y-splitter. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". Hi, Bringing up my re-controlled Vivendo Troodon 400 with a 6HC and 3HC. 00 and cannot get the stepper motors of the extruders to work. 8Hz when using P4. Trying to figure out why I can't run my extruder. I can put a dummy value on the T0 to verify the good functioning of the Titan. However,. M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. If that's not the case, we need to change the direction of rotation. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)M302 P1 ; cold extrude: G92 × 0 Y0 Z0 ; set current position to {X = 0,Y = 0,Z = 0} G92 E0 ;zero the extruded length: G1 F200 E0. microswitch) endstop. 1 Z0. 3 ; Cold-Section fan. It should be possible to make a Gcode file in a text. M302_P1_COLD_E. Ok I will try the bugfix branch with the config files you provided! G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C I need to print some PCL filament, which melts optimally at 100 C°. Wood filament wont extrude / print below 200deg. M302 Allow Cold Extrudes [Pnn/Snn/Rmm] Allow cold extrude, set min extrude & retract temps M302 P1 ; Allow cold extrusion M552 Set IP, enable/disable network in[Pnn / Snn/ Rnn] P(IPV4 address) S(0|1 enable|disable, M552 S1 P192. Any help would be greatly appreciated. However, a steps/mm value of 5. Thermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. 0. Re: Help with extruder feed calibration -. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. M122 shows some weird. Other possible causes are a bad stepper motor or cable. However, some firmware distributions might explicitly prevent these two commands of turning off the check. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. M302 by itself displays the current cold extrusion status (RepRapFirmware). Speaking of which. Can not get E0 to extrude, M302 P1 = still grey buttonsI am using Cura to slice a simple cube. Slic3r 1. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled: To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. G1 F900 ; set the feed-rate // Starting the print with Layer 0 ;Layer count: 2. 0. 1cc. 00°C/sec. I have a duex5 attached to a Duet Wifi with firmware 2. So currently I've been slowly working my way throw learning Marlin and Visual studio as well as trying to build my 3d printer with the SKR2. M302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. 3 (3. 13. 3V pins on E1STOP then enter M557 E1 S0 (FW 2. They should be about 100mm apart. 2"x12" backing boards 2"x4" studs 16. So are you still getting phase errors, or is that resolved? @jfavre said in Extruder motor not working. M302 P1 allows cold extrusion (RepRapFirmware). The printer functions and works as a normal syringe printer and is compatible with the Lulzbot Cura slicer software. I made a clay extruder for my printer. I just wondered if there was a way of "embedding" it in the config files so that it runs by default I'll set up a macro instead Thanks guysG-code for the 4th axis of the tangential knife after a slight modification {ASCI "conversion " (" to ";" and "A" to "E") allows you to run the code in the Marlin software. Only users with topic management privileges can see it. 155 5. M302: Allow cold extrudes add cancelling of the command; M561: Set Identity Transform - reset the transformation from calibration; Non specific G-codes Movement. Recently i have been testing the clay extruder connected to the Driver0 on Duet 3 Mainboard 6HC. Step 6. g: T0 ; select tool 0. oracledude 5 Dec 2021, 21:47. This is by far the only way I am able to see that the steppers can actually work through the board. g and resume. To test for this, with the power off swap the E0 connector on the Duet with another one e. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. On the X and Y we are using iHSS57-36-10 closed loop. 3 or later ;M17 A B G92 A0 B0 G1 A0 B0 F20000. Then reduce the distance, and stop just before the filament disappears into the hot end. 0. wordpress. Can you share output of M122 command and try cold extrude using M302 P1 it'll enable extrude button. To print at this lower temperature, g-code command M302 P1 was used to disable the printer’s cold extrusion checking. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Hi I am building a machine that is not a 3D printer but as I have liked a lot Duets for years now I decided to use one as a controller in this project too. 100". but if i want -z to go down shouldnt 0 be at the bottom? how would i swap that around, change the motor direction like you suggested in your last post?I did try a cold extrude M302 P1. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. Using Extruder-Motor by G-Code (after using M302 P1 to enable cold-extrusion) What catches my eyes is that the text "Heater1" etc. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. the ONLY command that should spin a motor before the printer homes is G28. 0C. 7 Move a motor on delta printer On delta printers, the X,Y and Z movements does not correspond to a motor movement, while for commissioning, you may want to operate each motor. Equipped with a remote controller designed for enterprise users and the newly upgraded Pilot 2 flight app, to improve the efficiency of drone operations. gco] Select SD file M23 filename. Click to Enlarge. 06. Pix4d often makes vertical surfaces to 45 deg where they meet the ground. . droftarts administrators @flyscha last edited by . Some common uses…. For firmware versions 1. @Phaedrux How would I combine the two M558 linesFilament is free for manual feeding" S2 ; blocking, but blocks DWC too M25 ; Pause (not like I wish to pause) G1 W{param. Or send the printer code "M302 P1" (with no quotes) to allow the extruder to turn without the hotend being hot. 0. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. g ; go to purge bucket. 0. You could do it it by turning off the safety limit which prevents cold extrusion. 3 ; Filter. droftarts administrators @flyscha last edited by . Extrude and retract a few times. Set the temperature (and. g. The M2 Carbine rifle is a fully automatic version of the M1A1. 3. 4. The prototype was outsourced to Oshpark. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. M302 P1 ; allow cold extrusion. Re-enable with. Extrusion Control in DWC unavailable, even after M302 P1. dmould. Without inserting the wire I tried to make a print and the extruder works. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. 499. g. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. @fcwilt said in Duet 3 Extruder control disabled: Just to be sure turn the bed heat on along with the extruder heat and see if that changes anything. What am I doing wrong? Thanks in advanceM302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. I am setting up a Delta printer with Ramps 1. This will restore the last configured Revo insert on the next restart of the firmware. 1 Reply Last reply Reply Quote 0. Business, Economics, and Finance. The hotend needs to be hot before the extruder motor will turn. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. 26" ; configure active-high endstop for low end on Y via pin null M574 Z1 S1 P"!P1. Users of single-extruder machines often put a T0 command at the end of config. M302. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. Make sure you clean out the heatblock and refit the nozzle properly, hot tightening it, etc. Then reduce the distance, and stop just before the filament disappears into the hot end. @agent0810 said in Homing advice: but then when i tried to home it sent the bed to the bottom Then we need to change the motor direction for Z like we did for the X and Y. com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. @deckingman Replacing the P1 with P0 in the config file was the trick! Now the retract option is available immediately when I activate the hot end heater, and when it reaches 160c, the extrude option is now available. In order to report the current status, run. @deckingman please find ;Cold extrusion M302 P1 ; allow cold extrusion ; Drives M569 P0 S1 ; physical drive 0 goes forwards M569 P1 S1 ; physical drive 1 goes forwards M569 P2 S1. 1 Reply Last reply Reply Quote 0. CryptoAs well as selecting the tool with e. retraction temperature 90. . Extrusion Control in DWC unavailable, even after M302 P1. the X motor. 168. I copied the first 2 layer g-code here, and I would like to know if anyone have an idea to solve this issue. dmould. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)You need to edit homeall. I have a Voron v0 (CoreXY) with LDO 14HS20-1504S for X and Y. Only users with topic management privileges can see it. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. 0 ; set drive mapping M350 X16 Y16 Z16 E16 I1 ; configure microstepping with interpolationThermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. @2:0 SENT: M302 RECEIVED: ok 0 RECEIVED: Cold extrusion allowed RECEIVED: wait Zum Test verwende ich immer Folgendes: G91 G1 E500 F3000 1-mal bearbeitet. Description The M2 Carbine is. Anytime I extrude a certain length of filament, the extruder retracts the same length it seems. I'm not sure if this. +Z should move the bed down. droftarts administrators @flyscha last edited by . g . 0C, min. Then reduce the distance, and stop just before the filament disappears into the hot end. First print: tiny layer shift at layer 6. Product Line: Ford Performance Parts Rear Main Seals. Summit Racing Part Number: FMS-M-6701-B302. extrusion temperature 160. what gcode do i need to send… Premium ExploreTo install this plugin, open DWC, go to Settings -> Plugins -> External Plugins and click on "Install Plugin". x) or M557 P1 S0 (FW >3. . Other possible causes are a bad stepper motor or cable. $egingroup$ That fix, sending M302 P1 (the P1 is important) and then M500 can be done in any program that can communicate directly with the printer. I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. g. However, I can't get the servo running with the new firmware. Viko. Re: How can I move E steppers? January 11, 2023 02:36AMFailure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. You want to leave that in case the bed or anything else still has a heater, and it wouldn't fix your problem anyway. droftarts administrators @flyscha last edited by . @dc42 That doesn't seem to work. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. The G Code already asks for cold extrusion M302 P1… I think the problem if it is all connected up as it should be is in the Config file assuming the Extruder logic is OK and hasn’t been damaged by having a motor output. And now even Col Extrusion M302 P1 is generating errors. How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. I'm at a dead end where I can't seem to get the E0 Stepper motor to. M569 P1. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. The code sends commands to an Octoprint instance. Try sending M302 S0 or M302 P1 to the printer to disable that and try the port again. 1 Reply Last reply Reply Quote 0. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. 86272-ad-b. . , appendicitis, cholecystitis,) Choice of first-line test will depend on likely origin of pain and suspected clinical diagnosis, for example: If acute. M302 P0. 4. Edit the M305 P1 command in file sys/config. Reply Quote. To test for this, with the power off swap the E0 connector on the Duet with another one e. M302 P1 disables the cold extrude safety. . If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. @jfavre said in Extruder motor not working. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. yello3d. A typical piece of GCode sent to a machine running RepRapFirmware might look like this (The meaning of these codes (and more) is. @Phaedrux said in Extruder motor not working. 0C. 36°C/sec measured -0. 16 07:24. Dear all i have 4 heaters, when i try to heat all of them at same time, it automatically goes to standby mode, what will be reason? when i individually heat them it works fine. Still no luck with Extrusion Control jogging buttons. P1: Acute abdominal pain (e. This will hopefully make it a bit easier for me to. So no need to use M302. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. g. I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. What should I look for? F. According to the docs, putting nothing or 0 means infinity. . 5. gcode - allow E-axis stepping regardless of nozzle temperature The contents of the micro SD card image now contains an Octoprint plugin to provide faster uploads of G-code files from the Octoprint host to the. La commande G-code M302 P1 permet l'extrusion a froid. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. Now I would like the printer to pause a print when the printer is running out of clay using an mechanical endstop. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Deactivate with "M106 P1 H-1". M302 P1 M563 P0 D0 T1 ;enable cold extrusion. M302 P0 S170. @o_lampe said in Error: Driver 5 does not support x1 microstepping: M584 X0 Y1 Z2 E5 ; set drive mapping M569 P5 S1 T25:25:25:25 ; physical drive 5 is external (DUE) M350 E1 ; no microsteps,. 1 Reply Last reply Reply Quote 0. CryptoThis topic has been deleted. I have a duex5 attached to a Duet Wifi with firmware 2. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. All models of the M1 carbine family (including the M2 and M3 carbines) fired a . M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. There is a web tool for this here which can make this easier for configuring another printer. 3. @patel said in how to change homing sequence: corexy printer setup how to change sequence homing x,y i am using M3D promega and i need to change sequence first y axis home after x axis manual working fine by hand trigger switch x limit and y limit See h. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. ; Configuration file for Duet WiFi (firmware version 2. M302 P1 ;allows cold extrusion with RepRap, otherwise "M302" alone works T0 ;selects tool0;M563 S1 ;allows for tool nomenclature compatibility between Slic3r and RepRap (Tools 0&1 vs Toos 1&2) I don't even want to do homing yet because my endstops are still screwed up, fortunately for my purposes I don't actually require them to work to. After replacing PCB managed to get everything up and running. g. See: Promega SupportBusiness, Economics, and Finance. I used to use "Pronterface" for that. Don't forget to send M302 P0 later to restore normal safety. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x. M302 P0. Compatible with the FlightHub 2 cloud platform and DJI Dock to achieve cloud collaboration and. 00" standard bore "competition" gasket for cast iron or aluminum cylinder heads on 302 and 351W production blocks. Other possible causes are a bad stepper motor or cable. Viko. @2:0 SENT: M302 RECEIVED: ok 0 RECEIVED: Cold extrusion allowed RECEIVED: wait Zum Test verwende ich immer Folgendes: G91 G1 E500 F3000 1-mal bearbeitet. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. The extrusion amount of the first layer is extremely low, but the other layers are fine. retraction temperature 90. M117 Let's make some filament!;Turn on fan;M106. the X motor. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). 2, Settings: FWRETRACT is not enabled, Slicer: Cura 4. M302 [None / Pnn/Snn/Rnn] Allow cold extrudes M302 M302 P1 M303 [Hnn / Pnn / Snn / Tnn / Ann] Run heater PID tuning M303 H1 P0. Reply Quote. And now even Col Extrusion M302 P1 is generating errors. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. Edit. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. M302 S160 ; lower cold extrusion limit to 160C {if filament_type[initial_tool]=="FLEX"}G1 E-4 F2400 ; retraction{else}G1 E-2 F2400 ; retraction{endif}. @jfavre Are you sure you have a tool selected (with T0, you will need that as well as the M302 P1)? What response did you get to M302 (before and after you set M302 P1)? Have you tried heating the nozzle? 1 Reply Last reply Reply Quote 0. It's simple. Re: How can I move E steppers? January 11, 2023 02:36AMSolved; M302 P1 command I have a duet2 wifi that I'm working on. @dc42 That doesn't seem to work. 03) ; executed by the firmware on start-up ; ; generated by RepRapFirmware Configuration Tool v2. Only users with topic management privileges can see it. e. The SMuFF is supposed to beep for 1 second. This topic has been deleted. W} F10000 ; grab filament for automatic feed while sensors. Zuletzt am 03. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPThermostatic control is turned on. Last edit at 01/11/2023 01:58AM by Dust. M98 Punload . Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected.